NCT05929196 | Completed | Diabetes


Feasibility Evaluation - Blood Glucose Level Monitoring by Microwave Metamaterial Sensor in Blood Samples.
Sponsor:

Czech Technical University in Prague

Brief Summary:

The goal of this clinical trial is to test microwave metamaterial glucose sensor on blood samples. It means to compare the results of glucose values obtained by microwave metamaterial sensor and by standard biochemical analyzer.

Condition or disease

Diabetes

Intervention/treatment

In vitro full blood diagnostic test.

Phase

Not Applicable

Detailed Description:

Participants will include physiological and pathological populations. Participants donate approximately 5 ml of blood sample. Three sample tubes will be collected from ten adult participants. In the first test tube, the blood glucose content will be determined by a validated biochemical analyzer (Roche, Switzerland). In the remaining volume of the blood sample, the dielectric parameters (relative permittivity and conductivity) will be estimated using a coaxial probe (Keysight, USA). Microwave metamaterial sensors with 5, 7 and 9 unit cells will be loaded with blood samples and the specific scattering matrices will be obtained using a vector network analyzer. The main monitored outcome measure will be the phase of parameter S21.}}

Study Type : Interventional
Estimated Enrollment : 21 participants
Masking : None (Open Label)
Primary Purpose : Basic Science
Official Title : Feasibility Evaluation - Blood Glucose Level Monitoring by Microwave Metamaterial Sensor in Blood Samples.
Actual Study Start Date : July 12, 2023
Estimated Primary Completion Date : July 17, 2023
Estimated Study Completion Date : September 1, 2023
Arm Intervention/treatment

Experimental: Blood sample donator

The participant donates approximately 5 ml of blood sample.

Diagnostic Test: In vitro full blood diagnostic test.

Ages Eligible for Study: 18 Years
Sexes Eligible for Study: All
Accepts Healthy Volunteers: Accepts Healthy Volunteers
Criteria
Inclusion Criteria
  • blood glucose can be measured with standard biochemical analyzer
Exclusion Criteria
  • minimum age limit 18 years

Feasibility Evaluation - Blood Glucose Level Monitoring by Microwave Metamaterial Sensor in Blood Samples.

Location Details


Please Choose a site



Feasibility Evaluation - Blood Glucose Level Monitoring by Microwave Metamaterial Sensor in Blood Samples.

How to Participate

Want to participate in this study, select a site at your convenience, send yourself email to get contact details and prescreening steps.

Locations


Not yet recruiting

Czechia, Central Bohemia

Kladno Regional Hospital, a.s.

Positively, Central Bohemia, Czechia, 27201

Loading...