NHS Lothian
This is a prospective cohort study assessing the survival of a new acetabula component which is based on the original Trident acetabular system (cementless shell) which is used for Total Hip Arthroplasty. The manufacturer recently introduced the evolution of this product, the Trident® II acetabular shell which was launched in 2017. This implant is CE marked and is now widely available for the UK market, however has minimal clinical outcomes data to support its use. As part of a stepwise introduction of devices to orthopaedic practice. This study will report the 10 year implant survival and patient functional outcomes of this new implant.
Arthritis of Hip
Hip Dysplasia
Hip Arthropathy
Hip Osteoarthritis
Stryker Trident® II HA coated cementless acetabula component
Not Applicable
125 patients will be recruited at a single-centre as part of a, phase-4 post-market surveillance, prospective cohort study This is a 10-year study of the Trident II acetabular component as part of total hip replacement at the Royal Infirmary of Edinburgh, NHS Lothian. Patients will receive a Trident® II acetabular component as part of primary total hip arthroplasty at the study centre. This component is CE marked and widely available for use by UK surgeons. The Trident® II shells are HA coated, cementless, press-fit acetabular shells composed of a Titanium (Ti-6Al-4V) substrate featuring a CpTi roughened surface with PureFix™ HA. The cup is available in a range of sizes and is indicated for primary and revision procedures. A standard operative technique will be employed by all study surgeons, using the posterior approach. The routine post-operative patient care protocol of the study centre will be employed. 10 year implant survival is the primary aim, but in addition functional and radiographical outcome will be assessed a 1, 2, 5, 7 and 10 years.
Study Type : | Interventional |
Estimated Enrollment : | 125 participants |
Masking: | None (Open Label) |
Primary Purpose: | Treatment |
Official Title: | Nexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE): A Longitudinal Cohort Study of the Hydroxyapatite Coated Trident II Acetabular System in Total Hip Arthroplasty |
Actual Study Start Date : | June 1, 2022 |
Estimated Primary Completion Date : | May 1, 2024 |
Estimated Study Completion Date : | February 2034 |
Arm | Intervention/treatment |
---|---|
Experimental: Trident® II HA coated shells Patients will receive a Trident® II acetabular component as part of primary total hip arthroplasty at the study centre. This component is CE marked and widely available for use by UK surgeons. The Trident® II shells are HA coated, cementless, press-fit acetabular shells composed of a Titanium (Ti-6Al-4V) substrate featuring a CpTi roughened surface with PureFix™ HA. |
Device: Stryker Trident® II HA coated cementless acetabula component |
Ages Eligible for Study: | 18 Years to 75 Years |
Sexes Eligible for Study: | All |
Accepts Healthy Volunteers: | No |
Want to participate in this study, select a site at your convenience, send yourself email to get contact details and prescreening steps.
Recruiting
NHS Lothian
Edinburgh, Lothian, United Kingdom, EH16 4SA